BABFAR HAS THE
RIGHT SIZE
HEATING SOLUTION FOR YOU!
|
|
This
is part of our laydown area
|

|

AH
Series
|
Model
|
AH-4
|
AH-9
|
AH-15
|
AH-20
|
|
Length (inch)
|
60
|
84
|
86
|
130
|
|
Width
|
24
|
34
|
40
|
56
|
|
Height
|
26
|
36
|
42
|
51
|
|
Weight (lbs)
|
450
|
880
|
1,200
|
1,200
|
|
ACFM (Blower)
|
1,800
|
5,000
|
9,000
|
12,000
|
|
Input BTU/hr(max)
|
390,000
|
950,000
|
1,500,000
|
2,000,000
|

DF-BG Series (1.8-9)
|
Model
|
DF 1.8 BG
|
DF 4 BG
|
DF 6 BG
|
DF 9 BG
|
|
Width
|
24"
|
46"
|
46"
|
64"
|
|
Length
|
84"
|
108"
|
132"
|
164"
|
|
Height
|
30"
|
44"
|
48"
|
68"
|
|
Weight (lbs)
Approximate
|
400 lbs.
|
1,100 lbs.
|
1,600 lbs.
|
2,200 lbs.
|
|
A.C.F.M.'s
|
1800
|
4,000
|
6,000
|
9,000
|
|
Maximum BTU's
|
380,000
|
750,000
|
1,300,000
|
1,800,000
|
|
Discharge Temperature
|
250º
|
250º
|
250º
|
250º
|
|
Natural Gas
High Pressure
|
NA
|

|

|

|
|
Natural Gas
Low Pressure
|
NA
|
NA
|

|

|
|
Liquid Propane
|

|

|

|

|
|
Motor H.P.
|
1
|
1 or 3
|
3
|
5
|
|
Phase
|
1
|
1
|
1
|
3
|
|
Voltage
|
115
|
220
|
220/480
|
220/480
|
|
Minimun Breaker
|
30 amp.
|
30 amp.
|
30 amp.
|
30 amp.
|
|
Duct Size
|
10"
|
16"
|
18"
|
24"
|

DF-BG
Series (11-21)
|
Model
|
DF 11 BG
|
DF 17 BG
|
DF 21 BG
|
|
Width
|
72"
|
84"
|
90"
|
|
Length
|
168"
|
176"
|
186"
|
|
Height
|
72"
|
89"
|
96"
|
|
Weight (lbs)
Approximate
|
2,500 lbs.
|
3,900 lbs.
|
4,500 lbs.
|
|
A.C.F.M.'s
|
11,000
|
17,000
|
21,000
|
|
Maximum BTU's
|
2,300,000
|
3,800,000
|
4,500,000
|
|
Discharge Temperature
|
250º
|
250º
|
250º
|
|
Natural Gas
High Pressure
|

|

|

|
|
Natural Gas
Low Pressure
|

|

|

|
|
Liquid Propane
|

|

|

|
|
Motor H.P.
|
5
|
7 1/2
|
10
|
|
Phase
|
3
|
3
|
3
|
|
Voltage
|
220/480
|
220/480
|
220/480
|
|
Minimun Breaker
|
30 amp.
|
30 amp.
|
30 amp.
|
|
Duct Size
|
24"
|
32"
|
32"
|

Steam & Hot Water Heaters
|
Model
|
DS-21
Steam
|
DS-21
Hot Water
|
|
Length
|
173"
|
173"
|
|
Width
|
96"
|
96"
|
|
Height
|
76"
|
76"
|
|
Weight
|
8100
lbs.
|
8100
lbs.
|
|
A.C.F.M.
|
21,000
|
21,000
|
|
Maximum
BTU
|
4,500,000
|
4,500,000
|
|
Motor
HP
|
20
|
20
|
|
Phase
|
3
|
3
|
|
Voltage
|
220/480
|
220/480
|
|
Minimum
Breaker
|
60/40
amp
|
60/40
amp
|
|
Duct
Size
|
32"
|
32"
|

|
Indirect Fired Heaters
|
Model
|
IDF 2T
|
IDF2 TK
|
IDF 17
|
IDF 21
|
|
Width
|
32"
|
32"
|
96"
|
96"
|
|
Length
|
116"
|
116"
|
260"
|
285"
|
|
Height
|
60"
|
60"
|
107"
|
107"
|
|
Weight
|
1,400
|
1,800
|
18,000
|
22,000
|
|
A.C.F.M
|
2,000
|
2,000
|
17,000
|
21,000
|
|
Maximum BTU
|
500,000
|
500,000
|
3,800,000
|
4,500,000
|
|
Discharge Temperature
|
250º F
|
250º F
|
250º F
|
250º F
|
|
Natural Gas
|
N/A
|
N/A
|

|

|
|
Fuel Oil
|

|

|

|

|
|
Motor H.P.
|
3
|
11HP Kubota
|
15
|
25
|
|
Phase
|
1
|
*
|
3
|
3
|
|
Voltage
|
220 Volts
|
*
|
220/480
|
220/480
|
|
Min Breaker
|
30 amp
|
N/A
|
60/30
|
60/30
|
|
Duct Size
|
12"
|
12"
|
32"
|
32"
|
|
|
*IDF
2TK is a self contained Unit
|
Air
Ventilators
|
Model
|
CFM
|
Motor
HP
|
Phase/
Voltage
|
Spiral
Duct Size
|
|
AM-2
|
2,000
|
1
|
1ph 110 volt
|
10"
|
|
AM-4
|
4,000
|
3
|
1ph 220 3ph
220/480
|
16"
|
|
AM-6
|
6,000
|
5
|
1ph 220 3ph 220/480
|
18"
|
|
AM-9
|
9,000
|
5
|
1ph 220 3ph
220/480
|
24"
|
|
AM-11
|
11,000
|
5
|
3ph 220/480
|
24"
|
|
AM-17
|
17,000
|
7.5
|
3ph 220/480
|
32"
|
|
AM-21
|
21,000
|
10
|
3ph 220/480
|
32"
|
|
AM-24
|
24,000
|
10
|
3ph 220/480
|
32"
|
|
Copyright (c) 2007 Babfar Equipment Corporation. All